MidNite Solar MNSPD300-DC Surge Protector
Have questions?
Feel free to get in touch
Stock Availablility
- Millstone, NJ: 3
- Sacramento, CA: 5
Midnite Solar, Surge Protector Device, 3-wire, 385VDC, for 150/200/250VDC PV arrays and charge controllers, MNSPD300-DC
According to UL1449 rev3, the MidNite Solar 300V Surge Protector System (MNSPD) is a Type 2 device. It covers service panels, load centers, Classic, other charge controllers, off-grid PV combiners, 120/240 VAC circuits, or where the SPD is directly attached to the electronic device requiring safety on both AC and DC systems. ETL has listed it for the USA and Canada.
The MidNite Solar Surge-Protector Device (MNSPD) is a Type 2 device that provides protection to service panels, load centers, or where the SPD is directly attached to the electronic device that needs protection. It is designed for both AC and DC systems. The SPD can only have maximum security if it is properly mounted.
To optimize the necessary degree of security, the MidNite Solar SPD is available in four different models. The clamping voltage is reduced to a reasonable level that your device can tolerate without causing harm to the electronics. The MidNite Solar SPD voltage rating should be chosen based on the system's nominal voltage. To clamp 128,000 A, the response time is 8/20 s. Each unit has two LEDs that light up when the unit is turned on and there is power.
Surge safety for wires coming from a 12, 24, or 48 VDC PV array, DC wind generator, or DC hydroelectric turbine is offered by the MNSPD-115. The MNSPD-300-DC is suitable for 150 VDC systems as well as larger systems with sources up to 300 VDC. On 120/240 VAC split-phase circuits or two legs each on 208 VAC circuits, the MNSPD-300-AC can be used. The MNSPD-600 is intended for high-voltage grid-tie PV arrays or 480 VAC circuits with two legs each. A combiner box, DC or AC load core, or grid-tie inverter may all be outfitted with lightning protection. These devices can be mounted on your AC load center to protect your equipment from utility line spikes, as well as on AC wiring that runs outside the building to generators, pumps, or outbuildings. These surge arrestors fit into a 12" knockout and come with a five-year warranty on materials and workmanship.
Features
- User Friendly - Built to be simple to install and compatible.
Shipping Details
Small to medium sized items ship through FedEx. It typically takes between one and two business days for handling and between two and five days in transit. Transit time depends on how close you are to a warehouse. See the Will Call shipping option for warehouse locations.
If you need quicker shipping please email / call and we can do FedEx 2 day. info@ware.solar / (801) 899-6285
Shipping and handling:
0 lb - 4.99 lb: $25.98
5 lb - 9.99 lb: $33.83
10 lb - 17.99 lb: $44.89
18 lb - 25.99 lb: $52.27
26 lb - 33.99 lb: $61.06
34 lb - 44.99 lb: $73.63
Rails over 10' need to ship through an LTL carrier
Rails over 10' and under 13'
$448.55 - 0 lb - 200 lbs
$460.54 - 200.1 lb - 665 lb
$486.65 - 665.1 lb - 1160 lb
Rails over 13.1' and 15'
$579.01 - 0 lb - 400 lb
$615.40 - 400.1 lb - 720 lb
$636.37 - 720.1 lb - 840 lb
Save on shipping by combining the rails and panels on the same order.
These items need to ship through an LTL carrier
$248.46 - 0 lb - 200 lb
$277.78 - 200.1 lb - 500 lb
$293.16 - 500.1 lb - 1000 lb
Save on shipping by combining the panels and rails on the same order.
Will Call warehouse locations:
Arlington TX, Fort Lauderdale FL, Fontana CA, Las Vegas NV, Millstone NJ, Orlando FL, Sacrament CA, Tampa FL
Please email us your order and we will email you an invoice with the Will Call option. info@ware.solar